NEW Baudouin 800kW LNG CNG Natural Methane Gas HTG-800GF Generator Set
All French Baudouin engines are built with the best technology and components.
The engines are ISO 9001: 2008 certified; which demonstrates its commitment to quality under European standards.
Prime Power kVA/kW 1000/800
Rated speed r/min 1000
Fuel Types CNG, LNG, PNG, Oilfield Associated Gas, Coalmine Gas, Coalbed Gas, methane gas.
Introduction of Baudouin LNG CNG Natural Methane Gas Generator Set
This series generator sets choose high quality Man, Cummins, Weifang ricardo, Doosan natural gas engine assembled with alternators (Stamford, Faraday or other famous brand), the control system adopts PLC automatic controller. This series of natural gas generator can be used in natural gas power plant, school, hospital, oil field and others, as a 24-hour uninterrupted power or standby power.
Advantages of Baudouin LNG CNG Natural Methane Gas Generator Set
1) Low operating and maintenance costs
2) Longer machine life: Special design engine has longer life with overhaul time 20000hours.
3) Low Emissions due to advantage technologies
4) Easy operation: The HAITAI Gas Power Generator is easy to operate.
5) The HAITAI Gas Power Generator use most advanced lean burn technical for high efficiency
6) Powerful to ensure uninterrupted operation
7) Adapt to harsh conditions
8) Main parts like ECU, Gas Mixer, Pressure Regulator, etc are origin made in USA& Italy.
Economy
Fuel consumption for the load rate between 60% and 90% is optimized specially, such that low fuel consumption is guaranteed.
Environmental adaptability
Low temperature adaptability: The engine can start directly at -10? without auxiliary measures and smoothly at -30? by means of intake preheating.
High level of platform
The engine is modular in design with high level of platform, the maintenance parts of the whole series are universal.
KEY BENEFITS
Ensures the display continues to operate
in extreme cold weather conditions.
Provides true generator and mains (utility)
sensing.
Provides clear accurate power
measurement information.
Provides secure and simple off site
monitoring. All ports are continuously active.
Provides multiple installation options.
Makes the module ideal for standard and
electronic engine applications.
Tracks the amount of fuel being used and
sounds an alarm if over/under fuel use is
detected.
Ensures the control module can be used
with the latest in modern electronic engine technology.
Ensures the load can be transferred
manually/automatically between mains (utility) and generator power.
Ensures the control module is suitable for worldwide use.
ADDITIONAL FEATURES
Customisable status screens.
Multiple date & time scheduler.
Charge alternator failure alarm.
CAN engine manual speed control.
Manual fuel pump control.
Engine exerciser.kW & kV Ar overload protection.
Reverse power (kW & kV Ar) protection. Unbalanced load protection.
USB connectivity.
Backed-up real time clock.
Configurable Gencomm pages.
SMS messaging start & stop functionality.
Modem diagnostic display screens.
Remote display support (max 3 units)
PowerKit Gas Engine Datasheet
Ratings Definitions - COP
- Unlimited using time per year;
- Continuous power is the maximum power available at a constant load factor;
- No overload capability is allowed
Ratings Definitions - PRP
- Unlimited using time per year;
- The average load rate is no more than 70% over 24 hours;
- Overloading 10% for 1h within 12 hours of operation is allowed.
Ratings Definitions - ESP
- he annual operating time shall not exceed 200h;
- The average load rate shall not exceed 70% over24h operation cycle;
- No overload capability is allowed;
- The acceleration of starting of engines are carried out in accordance with
Q/WCG136.13, and there's no engine process. From acceleration of starting to calibration speed shall be completed within 10s. Natural aspirated engine,
when the environment temperature is below 5º, need to increase preheat facilities to ensure that engine water temperature above 30°.
When environment temperature over 5º, no preheating facilities are required.
Supercharged engine, when the environment temperature is below 10º, need to increase preheat facilities to ensure that engine water temperature
above 30º When environment temperature over 10º, no preheating facilities are required
LTP- No ability to overload;
- The annual operating time shall not exceed 500h while supplying a variable
electrical load.
DCP- It has 10% overload capacity;
- Annual run time is unlimited;
- Working under variable or continuous load of less than 100%;
- The power load shall not exceed 70% of the calibration power when the device is running continuously.
Descriptions- ISO 8528-1, ISO 3046, DIN6271+-5%
- All ratings are based on operating conditions under ISO 8528-1,ISO 3046, DIN6271. Performance tolerance of+-5%.
- Test conditions : 100 kPa, 25ºC air inlet temperature, relative humidity of
30%. Derating may be required for conditions outside these;
please contact the factory for details. - Power output curves are based on the engine operating with gas system, water pump and lubricating oil pump, without battery charging alternator,
fan and optional equipment
For over 100 years, Baudouin has designed and manufactured the highest quality diesel and gas engines for marine and power generation applications spanning 18C 4125 kVA. Our Network supports our customers in over 130 countries with specification, commissioning, service and genuine spare parts.
Global Headquarters: Cassis, France
Baudouin China At a Glance Location: Weifang, China
SPARE PARTS We provide a 12-month Warranty and full stock of spare parts.
SHIPPING We can arrange shipping from our yard to your door worldwide.
- We deliver to over 150 countries
Materials and specifications are subject to change without notice.
Featured machines in photos may include additional equipment. The specification do not necessarily show the standard version of the machine.
Ask our manager for available options.
09.00 - 17.00 hrs Monday - Friday
Not available on Saturday's or Sunday's
- No ability to overload;