NEW 350kW MAN Natural Gas industrial Gensets HTG-350GF for sale
ID:2811
Engineered and Manufactured by: MAN
International Certifications: EU, China, USA
Category: Natural Gas Genset
Popularity:
7552 view
NEW
Mileage Hrs/Kms: 0
Year of Manufacture:
The price: P.O.A.
QTY Available: 2
NOTICE
Please don't copy or download any of these photos for posting on the Internet or for promotional use. Please send us a personal message if you would like to use them.
Please don't copy or download any of these photos for posting on the Internet or for promotional use. Please send us a personal message if you would like to use them.
Description 350kW MAN Natural Gas industrial Gensets HTG-350GF
Do you still worry about product quality assurance?
Are you late in deciding to buy because of insufficient budget?
If you have these worries, stay and see.
NEW 350kW MAN Natural Gas industrial Gensets (50Hz Applications) HTG-350GF
COP (kW) 350/437.5
Engine Model MAN E3268LE212
Rated Frequnendy 50Hz
DSPL. (L) 17.2
Oil consumption (g/kWh) <0.3
HAITAI MAN series gas industrial gensets & CHPs are driven by MAN engines originally made in Germany, one of the world top engine brands all over the world.
This series generator sets choose high quality natural gas engine assembled with alternators
(Stamford, Faraday or other famous brand), the control system adopts PLC automatic controller.
Advantages of MAN Natural Methane Gas Generator Set
Reliable service life resulting from application-specific design
Powerful to ensure uninterrupted operation
Adapt to harsh conditions
Applications of Natural Methane Gas Generator Set
High reliable and outstanding performance due to field-tested technology
The engine design is based on continuous working of 24 hours per day, 7 days per week
High Power and maximum efficiency, the best ideal engine for applications of CHP, CCHP, Cogeneration and
distribution energy system
Low operating cost as a result of low levels of lubricant and fuel consumption, as well as extended service intervals(component stability)
Low emissions due to state-of-the-art combustion technologies
Low space requirements due to compact design
Long service life resulting from application-specific-design and tailored machinery-configuration
MAN Engine Overhaul Time is around 65000 hours.
ISO9001 and CE approval.
Fuel Types CNG, LNG, PNG, Oilfield Associated Gas, Coalmine Gas, Coalbed Gas, methane gas.
Control Panel (Deepsea, SomAp, Deif)
The DSE7310 is an Auto Start Control Module and the DSE7320 is an Auto
Mains (Utility) Failure Control Module suitable for a wide variety of single,
diesel or gas, gen-set applications
OPTIONS
General Container The internal space is divided into two spaces: engine room and control room, and inspection channels on both sides of the equipment inside the engine room.
Functional description 350kW MAN GENSET:
1) The container is equipped with a distribution box to provide power to all low-voltage loads in the engine room, such as horizontal radiator fans, control screens, lighting, exhaust (supply) fans (for horizontal distribution), chargers, electric heating (optional), oil pumps, electric heating (optional), and outdoor searchlights. It can also be responsible for controlling related equipment (according to project configuration requirements);
2) Two track suspension beams and a hoist are installed on the top of the engine room, with a lifting capacity of 0.5 tons per beam;
3) Inlet of engine air filter and the engine room are equipped with electric heating devices to avoid freezing and blockage (optional);
4) The floor of the machine room is equipped with an axial drive mechanism for the generator, which enables the generator to detach from the coupling by 200mm. (Optional)
5) If the indoor heating temperature in the machine room is not lower than 5 C deg., an insulation layer needs to be installed under the chassis of the machine room, and electric heating heaters (optional) are used inside the machine room;
6) One explosion-proof acoustic and visual alarm lamp is installed outside each machine room. The lighting inside the machine room is an explosion-proof LED lamp with emergency function. Other equipment and boxes do not need to be explosion-proof (optional).
7) Ladder: Install a simple ladder at a suitable position on the box;
8) Configure the fire protection system in the machine room: Install dry powder fire extinguishers as fire extinguishing devices (standard), and other flame detectors, methane leak detectors, smoke detectors, etc. as optional options;
9) Note: The specific configuration shall be subject to the actual situation of the project.
CHP system (Exhaust Heat Collector) CHP/ Cogeneration/ CCHP/ Trigeneration
1. The unique spiral winding structure increases the turbulence effect, and the heat exchange capacity per unit area is 3-7 times that of the traditional heat exchanger.
2. High heat transfer coefficient, high heat exchanger heat transfer efficiency, good heat transfer effect, high heat transfer coefficient up to 14000W/m·k, energy saving effect is remarkable.
3. Small size. With only one-tenth of the traditional tube and shell heat exchangers, it takes up less space and reduces infrastructure and installation and maintenance costs.
4. Using a small clearance design to increase the flow rate, the heat exchanger is not easy to foul, and the use and maintenance costs
are low.
5. Advanced design concept, the length of the heat exchange tube is 3-4 times the height of the cylinder, the material stays longer and the
heat transfer is more fully.
6. Spiral-wound elastic tube bundle design can effectively eliminate pipe vibration and stress due to thermal expansion and contraction deformation.
7. Unique 90 degree connection, heat exchangers all participate in heat exchange, no dead ends and stagnant areas, reduce fluid resistance.
8. Counter-current heat transfer, asymmetric flow design, in the vapor-liquid heat transfer field has other advantages that can not be compared with heat exchangers.
Automatic Paralleling and Gridconnect Control System
This system can connect generator sets in parallel or connect the generator set to the grid automatically.
Remote Control
Horizontal radiator
Oil and Water Heater
High Voltage Alternator 6.3kv and 10.5kv, High Voltage Electrical Control Cells (PT Cabinet)
CT Cabinet
High Voltage outgoing cabinet
DC Panel, Groud Resistance Cabinet and low voltage distribution cabinet etc)
Documentation:
engine and generator original technical data / controller operation manual /instruction and maintenance manual / test report / delivery list
The specification of the 350kW MAN Natural Gas industrial Gensets HTG-350GF
Genset Main Technical Data
Power Rating (kW/kVa) 350/437.5
MFG. Standards ISO 3046 & ISO8528
Rated Frequnendy 60Hz
Electrical Efficiency
40.0%
Heat Efficiency 47.7%
Total Efficiency 87.7%
Fuel consumption @100% load, m?/h 87.7
Control System ComAp or Equal
Emission
NOX<500mg/Nm3 , CO<750mg/Nm3
Gas Engine Main Technical Data
Engine Brand & Model MAN E3268LE212
Engine Type Four stroke, Turbo Charged, and air to water cooled , Lean Burn
Cylinder Arrangement V-form
Bore x Stroke (mm) 132x157
Displacement (L) 17.2
Compressin Ratio 12:1
Rated Speed (rpm)
1800
Rated Output Power (kW) 370
Lean Burn, Excess Air Factor (Lambda) 1.63
Rotation Diretion Anti-clockwise Viewed on Flywheel
Oil consumption (g/kWh) <0.3
Altternator Main Technical Data
Alternator Brand Leroy Somer or Equal
Model LSA Series
Standards ISO 8528-3, CE, ISO9001 and ISO 14001
Frequnendy (Hz) 60
Rated Voltage (V) 440 / 480
Excitation Method
Self-excited (AREP), Brushless, AVR
Phase / Connection
3 Phase 4 Wire, Y-Connecton
Power Fator (COS) 0.8 (adjustable)
Protection Level / Installation Class IP 23 / H
Open Type Dimension, mm 4700 X 1600 X 2100
Weight, kg 5700
Soundpoof Type
Dimension mm 5100 X 1700 X 2500
Weight kg 7500
Containerized Type
Prevailing Industry Standards: ISO3046,ISO8528,GB2820, BS5000PT99,AS1359,IEC34, DIN6271, BS5514.
ISO Standards: ISO9001:2008, ISO14001, ISO45001 (former OHSAS 18001)
National & Regional Comformity Standards: CE, UL, EPA, CSA and SONCAP etc.
Third Party Certification for Gensets: SGS, CCS, BV, ABS and DNV-GL etc.
Power Rating (kW/kVa) 350/437.5
MFG. Standards ISO 3046 & ISO8528
Rated Frequnendy 60Hz
Electrical Efficiency
40.0%
Heat Efficiency 47.7%
Total Efficiency 87.7%
Fuel consumption @100% load, m?/h 87.7
Control System ComAp or Equal
Emission
NOX<500mg/Nm3 , CO<750mg/Nm3
Gas Engine Main Technical Data
Engine Brand & Model MAN E3268LE212
Engine Type Four stroke, Turbo Charged, and air to water cooled , Lean Burn
Cylinder Arrangement V-form
Bore x Stroke (mm) 132x157
Displacement (L) 17.2
Compressin Ratio 12:1
Rated Speed (rpm)
1800
Rated Output Power (kW) 370
Lean Burn, Excess Air Factor (Lambda) 1.63
Rotation Diretion Anti-clockwise Viewed on Flywheel
Oil consumption (g/kWh) <0.3
Altternator Main Technical Data
Alternator Brand Leroy Somer or Equal
Model LSA Series
Standards ISO 8528-3, CE, ISO9001 and ISO 14001
Frequnendy (Hz) 60
Rated Voltage (V) 440 / 480
Excitation Method
Self-excited (AREP), Brushless, AVR
Phase / Connection
3 Phase 4 Wire, Y-Connecton
Power Fator (COS) 0.8 (adjustable)
Protection Level / Installation Class IP 23 / H
Open Type Dimension, mm 4700 X 1600 X 2100
Weight, kg 5700
Soundpoof Type
Dimension mm 5100 X 1700 X 2500
Weight kg 7500
Containerized Type
Prevailing Industry Standards: ISO3046,ISO8528,GB2820, BS5000PT99,AS1359,IEC34, DIN6271, BS5514.
ISO Standards: ISO9001:2008, ISO14001, ISO45001 (former OHSAS 18001)
National & Regional Comformity Standards: CE, UL, EPA, CSA and SONCAP etc.
Third Party Certification for Gensets: SGS, CCS, BV, ABS and DNV-GL etc.